MS power control
|
||||
Parameter
|
Description
|
Range
|
Ericsson Dafault Value
|
Remarks
|
DMPSTATE
|
Dynamic MS power control state
|
ACTIVE, INACTIVE
|
INACTIVE
|
-
|
SSDES
|
Defines the target value for the
desired signal strength uplink measured by the BTS during the stationary
phase.
|
47 to 110 dbm
|
85
|
Lower desired SS to prevent
interference in Urban Area
|
INIDES
|
Defines the target value for the
desired signal strength uplink measured by the BTS during the initial phase.
|
47 to 110 dbm
|
70
|
-
|
SSLEN
|
Length of stationary signal strength
filter
|
3 to 15 SACCH periods
|
5
|
The value of SSLEN > INILEN.
|
INILEN
|
Length of initial signal strength
filter
|
0, 2 to 5 SACCH periods
|
2
|
Faster when value is lower
|
LCOMPUL
|
Path loss compensator factor, uplink.
When set to zero, no power control towards SSDES is performed.
|
0 to 100%
|
70
|
-
|
PMARG
|
Power margin on the new channel at
assignment, intra-cell handover and subcell change and on the old channel at
assignment failure or handover failure.
|
0 to 20 dB
|
8
|
-
|
QDESUL
|
Desired quality uplink
|
0 to 70 dtqu
|
20
|
-
|
QLEN
|
Length of the uplink quality filter
|
1 to 20 SACCH periods
|
8
|
-
|
QCOMPUL
|
Quality deviation compensation
factor, uplink
|
0 to 60 %
|
30
|
-
|
REGINT
|
Regulation interval, stationary,
uplink
|
1 to 30 SACCH periods
|
3
|
MS power regulation is performed at
intervals specified by REGINT. A new power order is issued only if the
calculated power level is different from the current MS power level.
|
DTXFUL
|
Number of measurements periods before
the full set of measurements are used
|
0 to 40 SACCH periods
|
5
|
-
|
GSM MS power control Parameter
Subscribe to:
Post Comments (Atom)
2 comments:
good one
Nice docs
Post a Comment