Huawei Power Control 3 Parameter
Parameter ID | Parameter Name | Recommended
Value |
MRMISSNUM | MRMissNumber | 5 |
ULADJPRD | PwrCtrlULAdjPeriod | 3 |
DLADJPRD | PwrCtrlDLAdjPeriod | 3 |
SDMRCUTNUM | SdMrCutNum | 1 |
TCHMRCUTNUM | TchMrCutNum | 3 |
DLREXLEVEXPFLTLEN | DLRexLevExponentFilterLen | 3 |
DLREXQUALEXPFLTLEN | DLRexQualExponentFilterLen | 3 |
DLREXLEVSLDWINDOW | DLRexLevSlideWindow | 1 |
DLREXQUALSLDWINDOW | DLRexQualSlideWindow | 1 |
DLREXLEVADJFCTR | DLRexLevAdjustFactor | 3 |
DLREXQUALADJFCTR | DLRexQualAdjustFactor | 6 |
DLREXLEVHIGHTHRED | DLRexLevHighThred | 20 |
DLREXLEVLOWTHRED | DLRexLevLowthred | 20 |
DLFSREXQUALHIGHTHRED | DLFSRexQualHighThred | 16 |
DLFSREXQUALLOWTHRED | DLFSRexQualLowThred | 16 |
DLHSREXQUALHIGHTHRED | DLHSRexQualHighThred | 18 |
DLHSREXQUALLOWTHRED | DLHSRexQualLowThred | 18 |
DLAFSREXQUALHIGHTHRED | DLAFSRexQualHighThred | 14 |
DLAFSREXQUALLOWTHRED | DLAFSRexQualLowThred | 14 |
DLAHSREXQUALHIGHTHRED | DLAHSRexQualHighThred | 16 |
DLAHSREXQUALLOWTHRED | DLAHSRexQualLowThred | 16 |
DLMAXDOWNSTEP | DLMAXDownStep | 4 |
DLMAXUPSTEP | DLMAXUpStep | 8 |
ULREXLEVEXPFLTLEN | ULRexLevExponentFilterLen | 3 |
ULREXQUALEXPFLTLEN | ULRexQualExponentFilterLen | 3 |
ULREXLEVSLDWINDOW | ULRexLevSlideWindow | 1 |
ULREXQUALSLDWINDOW | ULRexQualSlideWindow | 1 |
ULREXLEVADJFCTR | ULRexLevAdjustFactor | 3 |
ULREXQUALADJFCTR | ULRexQualAdjustFactor | 6 |
ULREXLEVHIGHTHRED | ULRexLevHighThred | 18 |
ULREXLEVLOWTHRED | ULRexLevLowThred | 18 |
ULFSREXQUALHIGHTHRED | ULFSRexQualHighThred | 16 |
ULFSREXQUALLOWTHRED | ULFSRexQualLowThred | 16 |
ULHSREXQUALHIGHTHRED | ULHSRexQualHighThred | 18 |
ULHSREXQUALLOWTHRED | ULHSRexQualLowThred | 18 |
ULAFSREXQUALHIGHTHRED | ULAFSRexQualHighThred | 14 |
ULAFSREXQUALLOWTHRED | ULAFSRexQualLowThred | 14 |
ULAHSREXQUALHIGHTHRED | ULAHSRexQualHighThred | 16 |
ULAHSREXQUALLOWTHRED | ULAHSRexQualLowThred | 16 |
ULMAXDOWNSTEP | ULMAXDownStep | 6 |
ULMAXUPSTEP | ULMAXUpStep | 8 |
SAICTHREDAPDTVALUE | Power Control threshold Adjust for SAIC | 3 |
FINESTEPPCALLOWED | 0.2dB Power Control Enable | NO |
PWRCTRLOPTIMIZEDEN | III Power Control Optimized Enable | NO |
ULFILTADJFACTOR | III UL Filter Adjust Factor | 3 |
DLFILTADJFACTOR | III DL Filter Adjust Factor | 3 |
ULRXLEVPROTECTFACTOR | III UL RexLev Protect Factor | 6 |
ULRXQUALPROTECTFACTOR | III UL RexQual Protect Factor | 75 |
DLRXLEVPROTECTFACTOR | III DL RexLev Protect Factor | 5 |
DLRXQUALPROTECTFACTOR | III DL RexQual Protect Factor | 55 |
AMRCALLPCALLOWED | Allow III Power Control For AMR | ON |
NONAMRCALLPCALLOWED | Allow III Power Control For Non-AMR | ON |