LTE Paging Parameter

Parameter Name
Parameter Description
Default Value
PagingId
The value component of the RDN.

maxNoOfPagingRecords
The maximum allowed number of paging records included in one Radio Resource Control (RRC) paging message. It is the allowed maximum number of UE that can be paged per paging occasion.
3
defaultPagingCycle
The paging cycle (also referred to as T) used by the RBS and broadcast in system information type 2. If the UE-specific Discontinuous Reception (DRX) cycle is provided in S1AP paging and has a smaller value than defaultPagingCycle, the UE-specific DRX cycle overrides defaultPagingCycle.
128
nB
Used to calculate the number and position of Paging Occasions (PO) and Paging Frames (PF).
The numerical value of nB depends on the value of the defaultPagingCycle (T) and can be set to one of the following values:
4T, 2T, T, 1/2T,1/4T, 1/8T, 1/16T, 1/32T
When nB is set to T, 2T or 4T, it determines the number of POs per PF, and the PO position in PF.
When nB is set to a value smaller than T, it affects the System Frame Number of the PF, the position of PO in the PF, and also distribution of UE into groups with the same PF.
When nB is set to a  smaller value, the groups are fewer but larger, or more but smaller.
T
pagingDiscardTimer
The length of time a received paging is retained or queued in the RBS before it is discarded. The timer should be set to the same (or smaller) value as the paging resend timer in MME (T3413). This setting  prevents the RBS from retaining or sending an old paging after the re-sent copy is received from the MME.
3