GSM CELL LOAD SHARING Parameter


CELL LOAD SHARING
Parameter
Description
Range
Ericsson Default Value
Remarks
CLSSTATE
Cell load sharing active/inactive for an individual cell
ACTIVE, INACTIVE
INACTIVE
For CLSSTATE activation to have effect, CLSSTATE must be activated
CLSACC
Percentage of available full rate capable traffic channels in a target cell at or below which no handovers due to Cell Load sharing will be accepted
1 to 100 %
40%
-
CLSLEVEL
Percentage of available full rate capable traffic channels at which or below which Cell load sharing evaluations are initiated.
0 to 99 %
20%
The value of of CLSLEVEL must be less than the value of CLSACC
HOCLSACC
Handover due to cell load sharing accepted to this cell
ON, OFF
OFF
-
RHYST
Hysteresis reduction parameter - determines how much hysteresis can be reduced in the cell load sharing evaluation
0 to 100 %
75%
-
CLSRAMP
Cell load sharing ramping time parameter.
0 to 30 seconds
5 seconds
The interval during which value of RHYST is ramped up from zero to the final value.

GSM Overlaid Subcell Locating data


Overlaid Subcell Locating data
Parameter
Description
Range
Ericsson Dafault Value
Remarks
LOL
Pathloss threshold.
0 to 200

Pathloss threshold. It defines the OL subcell coverage border in terms of the pathloss from the serving cell.
LOLHYST
0 to 63

Hysteresis for the pathloss criterion during evaluations for the OL subcell coverage.
DTCB:

-63 to 63
-63
Distance to cell border threshold. It defines the OL subcell coverage border in terms of the signal strength difference between the active channel and the strongest neighbouring BCCHs.
DTCBHYST

0 to 63

Hysteresis for the DTCB criterion during evaluations for the OL subcell coverage.
NDIST

0 to 63

Distance to cell border additional threshold.
NNCELLS

1 to 5

Number of strongest neighbouring BCCHs for the DTCB criterion. See the comments for NDIST.
TAOL

0 to 61 Bit periods (bp)

Timing advance threshold. It defines the OL subcell timing advance border
TAOLHYST

0 to 61 Bit periods (bp)

Hysteresis for the timing advance criterion during evaluations for the OL subcell coverage.

GSM Intra cell handover Parameter



Intra cell handover
Parameter
Description
Range
Ericsson Dafault Value
Remarks
IHO
Intra handover switch: ON - Intra cell handover is allowed; OFF - Intra cell is not allowed
ON, OFF
OFF
-
TMAXIHO
Timer for handover counter
0 to 60 seconds
6
-
TIHO
Intra cell handover inhibition timer
0 to 60 seconds
10
-
MAXIHO
Maximum number of consecutive intra-cell handovers
0 to 15
3
-
QOFFSETUL
Offset for quality uplink
 -50 to +50 dtqu
0
-
QOFFSETDL
Offset for quality downlink
 -50 to +50 dtqu
0
-
SSOFFSETUL
Offset for signal strength uplink
 -30 to +30 db
0
-
SSOFFSETDL
Offset for signal strength downlink
 -30 to +30 db
0
-

GSM Locating urgency cell Parameter


Urgency Conditions for Handover [Locating Algorithm]
Parameter
Description
Range
Ericsson Dafault Value
Remarks
TALIM
Timing advance limit for handover - Urgency detection parameter
0 to 63 (normal cell) Bits periods (bp)
62
TALIM determines the maximum timing advance that the MS is recommended to use in the cell
PSSBQ
Signal strength penalty when handover due to bad quality. This penalty  is valid during PTIMBQ
0 to 63 db
10 dB
-
PSSTA
Signal strength penalty when handover doe to too large timing advance. It is valid during PTIMTA
0 to 63 db
63
-
PTIMBQ
Penalty time when handover due to bad quality
0 to 600 seconds
10
-
PTIMTA
Penalty time when handover due to too large timing advance
0 to 600 seconds
10
-
QLIMDL
Quality limit downlink for handover. Urgency detection parameter
0 to 100 dtqu
55
Deci transformed GSM quality units (dtqu).
QLIMUL
Quality limit uplink for handover. Urgency detection parameter
0 to 100 dtqu
55
Deci transformed GSM quality units (dtqu).